EXPERIMENTAL STUDY ON REGENERATING FOULED EGR COOLER BY NTPI TECHNOLOGY |
Y. Y. CHEN, Y. X. CAI, X. H. LI, Y. X. SHI, Y. ZHENG |
Jiangsu University |
|
|
|
ABSTRACT |
In order to investigate the regeneration effect of non-thermal plasma injection (NTPI) technology on fouled exhaust gas recirculation (EGR) cooler, NTPI regeneration apparatus and EGR cooler performance test system were built up. Results showed that non-thermal plasma (NTP) could peel off the deposit layer and improve the heat exchange performance effectively. The carbon removal energy efficiency of this NTPI regeneration setup was 22.46 g/kWh and the O3 utilization ratio was 96.50%. To get a deeper understanding of the regeneration effect, thermo-gravimetric analysis (TGA) and Fourier transform infrared spectroscopy (FTIR) were introduced to investigate the variation of deposit layer |
Key Words:
NTPI, EGR cooler performance, Regeneration effect, TGA |
|
|
|